BExCS110L2DPFAC230AB1P1R/R - Đèn - Còi hụ báo động E2S
BExCS110L2DPFAC230AB1P1R/R - Đèn - Còi hụ báo động E2S Repair Service On Stand A9, Hall 1 at OMC, the Offshore Marine Conference,...
Output module BSJ-310
Output module BSJ-310
The output terminal sinks to 0V when activated. 24V is available on the screw terminals. The module will automatically detect its own address; no Dip-switch or jumper settings are required.
Output module BSJ-310 Datasheet Repair Service Output module with 8 open transistor (collector), non-monitored outputs. The o...
Communication module BSL-310
Communication module BSL-310
The module provides the following:
- RS-232 interface with hand-shake, all lines galvanically isolated to allow floating reference
- Built-in battery monitoring with control outputs for activation of charger/battery
- Monitoring of earthing faults
Communication module BSL-310 Datasheet Repair Service AutroSafe communication module, serves as an interface for the common int...
Input module BSE-320
Input module BSE-320
The inputs have a common connection to an external source, 24V DC. Each input is activated by pulling the terminal to 0V, typically by an open collector output. The module will automatically detect its own address, no Dip-switch or jumper settings are required. The module is intended to be mounted in a closed cabinet. Ambient light should be avoided.
Input module BSE-320 Datasheet Repair Service Input module with 8 non-monitored and galvanically isolated inputs for digital ...
Power supply module BSS-310A
Maximum 2 such modules can be used in each cabinet.
Power supply module BSS-310A Datasheet Repair Service AutroSafe power supply module for converting unregulated battery voltage ...
OBSOLETE - Modbus converter - BSL-330/1
OBSOLETE - Modbus converter BSL-330/1
The converter is connected to the AutroSafe via the AutroCom protocol. It communicates with both protocols by means of the conversion software. A master Modbus device polls the BSL-330 converter for reading its registers. It expects a response within a defined time period. Communication can be over various serial mediums. The one used here is the Modbus RTU protocol over an RS485 link (RS232).
The BSL-330 is available in four versions:
- BSL-330/1: AutroSafe Modbus converter slave RS485
- BSL-330/2: AutroSafe Modbus converter master RS485
- BSL-330/3: AutroSafe Modbus converter slave RS232
- BSL-330/4: AutroSafe Modbus converter master RS232
OBSOLETE - Modbus converter BSL-330/1 Datasheet Repair Service Modbus converter for interfacing various PLC equipment to AutroS...
Input unit BN - 500/EX
Input unit BN-500/EX
The input unit is used to interface different types of signal devices of ON/OFF type onto the interactive detector loop.
The SelfVerify function ensures the highest grade of reliability and reduces the need for manual testing, because all units comprising this function are automatically checked once every 24 hours.
Input unit BN-500/EX Datasheet Repair Service With one monitored input, for connection of external alarm contacts etc. Approved...
Ultrasonic sensors UM30 - 6037671
Ultrasonic sensors UM30
- PERFORMANCE
Operating range, limiting range 200 mm ... 1,300 mm, 2,000 mm Target Natural objects Resolution ≥ 0.18 mm Repeatability ± 0.15 % 1) Accuracy ± 1 % 1) 2) Temperature compensation ✔ Response time 92 ms Switching frequency 8 Hz Output time 23 ms Ultrasonic frequency (typical) 200 kHz Detection area (typical) See diagrams Additional function Set switching mode: Distance to object (DtO) / Window (Wnd) / Object between sensor and background (ObSB), teach-in of switching output, set levels of switching outputs, Invertable switching output, set on delay switching output, temperature compensation, synchronization of up to 10 sensors, multiplexing: no cross talk of up to 50 sensors, set measurement filters: value filter, filter strength, adjustable sensitivity, foreground suppression and detection area, switch-off display, reset to factory default - 1) Referring to current measurement value.
- 2) Temperature compensation can be switched off, without temperature compensation: 0.17 % / K.
- INTERFACES
Switching output 1 x NPN (200 mA) 1) Multifunctional input (MF) 1 x MF Hysteresis 20 mm - 1) NPN: HIGH = ≤ 2 V / LOW = UV.
- MECHANICS/ELECTRONICS
Supply voltage Vs DC 9 V ... 30 V 1) 2) Power consumption ≤ 2.4 W 3) Initialization time < 300 ms Design Cylindrical Housing material Nickel-plated brass, PBT
Display: TPU
Ultrasonic transducer: polyurethane foam, glass epoxy resinConnection type Male connector, M12, 5-pin Indication LED display, 2 x LED Weight 150 g Sending axis Straight Enclosure rating IP67 Protection class III - 1) Limit values, reverse-polarity protected Operation in short-circuit protected network: max. 8 A, class 2.
- 2) 15 V ... 30 V when using the analog voltage output.
- 3) Without load.
- AMBIENT DATA
Ambient temperature operation –25 °C ... +70 °C Ambient storage temperature –40 °C ... +85 °C
- CLASSIFICATIONS
ECl@ss 5.0 27270804 ECl@ss 5.1.4 27270804 ECl@ss 6.0 27270804 ECl@ss 6.2 27270804 ECl@ss 7.0 27270804 ECl@ss 8.0 27270804 ECl@ss 8.1 27270804 ECl@ss 9.0 27270804 ETIM 5.0 EC001846 ETIM 6.0 EC001846 UNSPSC 16.0901 41111960
Technical drawings





Ultrasonic sensors UM30 Repair Service PERFORMANCE Operating range, limiting range 200 mm ... 1,300 mm, 2,000 mm Target Nat...
PROVA 710 Micro-Ohmmeter
PROVA 710Micro-Ohmmeter
■ Best resolution 1μΩ
■ Basic accuracy 0.25%
■ Four terminal Kelvin measurement
■ Manual or Auto Range
■ Measurement of resistive and inductive materials
■ Programmable Hi-Lo alarm with memory of 20 data
■ Readings Hold function
■ Cable length measurement (Meter or Feet)
■ Memory of 3,000 measurement data
■ Large LCD (5-digit) with backlight
■ Rechargeable lithium battery and AC adaptor
■ Low battery (voltage) alarm
■ Low power consumption
■ Communicate with PC via RS232C (to USB bridge) cable.
■ Built-in calendar clock
■ Built-in battery charging circuit
■ Application: Coil resistance of electric motor; Contact resistance of switch and relay; Resistance of bus bar, breaker, fuse, inductance and shunt; etc.
PROVA 710Micro-Ohmmeter Datasheet Repair Service ■ 10A (60mΩ) max. test current ■ Best resolution 1μΩ ■ Basic accuracy 0.25%...
VFPS1-4750PL-WN - Biến tần Toshiba - Toshiba Inverter
Manufacturer: | Toshiba |
Series: | VF-PS1 |
Model: | VFPS1-4750PL |
Application: | pumps / fans |
Capacity, kW: | 75 |
Current, А: | 160 |
Main power supply, V: | 380-480 |
Phase: | 3 |
Output frequency, Hz: | 0,01-500 |
Enclosure: | IP20 |
Overload capacity, % per 1 min.: | 120 |
Acceleration time, sec: | 0,01-6000 |
Deceleration time, sec: | 0,01-6000 |
EMC filter: | + |
Braking unit: | + |
Analog input: | 2 |
Digital input: | 2 |
Analog output: | 1 |
Digital output: | 4 |
Relay output: | 2 |
RS485 (Modbus RTU): | + |
Starting torque: | 150% |
PID: | PID-Regulation |
V/f control mode: | - |
Vector control with feedback: | + |
Sensorless vector control: | + |
Operation temperature, °С: | -10.....+60 |
Storage temperature, °С: | -25.....+70 |
Dimensions (W x H x D), mm: | 320x630x290 |
Weight, kg: | 48 |
VFPS1-4750PL-WN - Biến tần Toshiba - Toshiba Inverter Repair Service Technical Specification Manufacturer: Toshiba Series: ...
Biến tần TOSHIBA - Toshiba Inverter - VFS15-4037PL-W1
Manufacturer | TOSHIBA | |
Type of module | vector inverter | |
Max motor power | 4kW | |
Inverter output voltage | 3 x 380V AC | |
Three-phase power supply voltages range | 3 x 380...500V AC | |
Input 1 properties | 2 inputs for setting motor rotational speed by signals 0...10V, 4...20mA, 0...20mA or by means of the external potentiometer | |
Voltage output | 0...10V | |
Current output | 0/4-20m | |
Electrical connection | screw terminals | |
Mounting | for wall mounting | |
The programming method | keypad and potentiometer | |
Protection | motor earth fault, overload, short-circuit | |
Kind of display used | LED | |
Supply current | 9.5A | |
Series | VFS15 | |
Possible applications | see |
- 15 fixed speeds
- 2 analog inputs
- 3 digital outputs ( + 2 relay outputs)
- MODBUS RTU
- RS485/422 (max 115kB/s)
- disturbance filter
- PID regulator
- three combined settings
- Gross weight: 3.05 kg
Biến tần TOSHIBA - Toshiba Inverter - VFS15-4037PL-W1 Data Sheet Repair Service Manufacturer TOSHIBA Type of module vector in...
Model 6000 Inclinometer Probes
Model 6000 Inclinometer Probes Data Sheet Manual Repair Service The Model 6000 Inclinometer Probe is used in conjunction with...
Safety system PNOZmulti – Communication and fieldbus modules
Specifications
Datasheets, Documents & Links
![]() |
![]() |
Safety system PNOZmulti – Communication and fieldbus modules Repair Service Specifications Item Number: 773812 UP...